Browse Source

Interworking: Re-trigger scan if no connect attempt is done

For one specific case when running with Interworking enabled the
re-initialisation of the scan timer is missing. This makes auto connect
to a configured network fail.

The case is:
- Interworking credentials available, but do not match
- Auto interworking is enabled (auto_interworking=1)
- Interworking auto select is disabled (i.e., this is from
  auto_interworking=1, not from INTERWORKING_SELECT auto)
- No configured (enabled and non blacklisted) networks are present
  in scan results list with full match
- Interworking finds matching networks (it does not do full security
  policy match)

This patch covers the case and re-initialises the scan timer to allow
search for a suitable network to continue.

Signed-off-by: Mikael Kanstrup <mikael.kanstrup@sonymobile.com>
Mikael Kanstrup 10 years ago
parent
commit
b77aeae732
1 changed files with 3 additions and 2 deletions
  1. 3 2
      wpa_supplicant/interworking.c

+ 3 - 2
wpa_supplicant/interworking.c

@@ -2397,9 +2397,10 @@ static void interworking_select_network(struct wpa_supplicant *wpa_s)
 		if (interworking_find_network_match(wpa_s)) {
 			wpa_printf(MSG_DEBUG, "Interworking: Possible BSS "
 				   "match for enabled network configurations");
-			if (wpa_s->auto_select)
+			if (wpa_s->auto_select) {
 				interworking_reconnect(wpa_s);
-			return;
+				return;
+			}
 		}
 
 		if (wpa_s->auto_network_select) {